Server room air conditioners are typically sized in kW (kilo-watts) or BTU (British Thermal Units). To quickly calculate the BTU for a server room, multiply the room dimensions in feet by 5. So for a small server room that is (30×20×16) x 5 = 48,000 BTU. To convert BTU to kWh (kilo-watt hours), multiply the BTU figure by 0.. So for this server room the kWh = 48,000 x 0. = 14.06kWh. This calculation does not take into account the room orientation (north or south) and whether there are any windows.
Goto Chengyue to know more.
With the UK experiencing one of the hottest summers since many server room air conditioners and datacentre cooling systems are facing extreme workloads. The issue is not the ambient temperature itself but the length of time that the higher than average temperatures have been around. For future upgrades and new system installations it may well become the norm to have to build in a heatwave factor to prevent disruption and potential system failures. So how do you size an air conditioner for a server room or datacentre?
The simplest view is that you list all the heat sources and install an air conditioner that will remove the heat and prevent the server room ambient temperature from going critical. The actual calculation is more complex and must take into account a number of other factors.
In any electrical installation, heat is wasted energy and results from a work-related process. The higher the energy efficiency, the more of the power input into a system results in output. The lower the energy efficiency the higher the heat wasted.
Within a server room or datacentre environment the power consumption of the server loads can be as high as 15kW per rack. At 95% efficient this can lead to up to 0.75kW of heat per server rack that will add to the ambient temperature.
Typical heat load measurement units include:
BTU
/hour whereBTU
= British Thermal UnitBTU
per hour)Traditionally BTU/hour has been the measurement unit of choice by Heating Ventilation and Air Conditioning (HVAC) professionals. BTU is approximately the energy needed to heat one pound of water by 1 degree Fahrenheit. 1 BTU is equal to 1,055 Joules or 252 calories or 0.293 watt-hour or the energy released from burning one match. In the IT world and especially server rooms and datacentres the trend is more towards use of Watts and kilowatts or kW as a unit of measure.
The first thing to do when calculating an air conditioning system is to audit the equipment within the room itself. The equipment list should include all electrical items within the room that will generate heat. Typical prime examples include:
UPS
systemsThe systems and equipment should be listed by make, model and preferably serial number on an audit spreadsheet and values placed against each item where possible for BTU/hour, kW heat output, energy efficiency, electrical supply phase (single or three phase) and electrical frequency. Most often this information can be taken from operating manuals, datasheets and manufacturers websites.
For smaller server rooms this approach will help to identify the amount of heat that must be tackled by the air conditioner, referred to as the thermal load, heat load or thermal gain. The most common type of air conditioner for a server room is a wall mounted version. Ceiling suspended air conditioners are also popular where feasible.
Whether the air conditioner is installed as a single unit or part of a set to share the load, environmental monitoring is a must have. This will not only provide regular reporting on the overall ambient within the server room but also alarm when temperatures start to rise because of a failure or intermittent fault within the air conditioning system. It is also important to monitor room ambient as server rooms tend not to have automatic fire suppression equipment systems and their insulation (to comply with insurance company policies) may be higher than a typical office, leading to a greater potential for heat rise and containment.
For larger facilities a more complex cooling system will be required that could include computer room air conditioners (CRACs), computer room air handlers (CRAHs) and in-row air conditioners. Other factors to consider include:
BTU
For more information, please visit precision ac for server room.
per person)ASHRAE
TC9.9 https://tc.ashraetcs.org/documents/ASHRAE_TC_Power_White_Paper_22_June__REVISED.pdf)PUE
)Whilst there are general rules of thumb to work to when sizing a cooing system for a datacentre (CRAC unit size = 1.3 x IT load), it is more common for large installations like this to be thermodynamically modelled. This is a critical point of concern as in a server room it may be relatively easy to upgrade a poorly sized air conditioner.
In a large datacentre space, it is important to optimise both the cooling and energy efficiency so that there are no hot-spot areas and the least amount of energy is used to achieve the required ambient. Most server rooms and datacentres will look to achieve an ambient temperature around 20-25˚C with the ASHRAE standard TC9.9 used as a guideline. Potentially higher ambients can be allowed as most IT equipment will work up to 30˚C or higher but this higher temperature is detrimental to UPS batteries (if stored within the room) and uncomfortable as a working environment.
Useful BTU Cooling Formulae:
BTU
= Total wattage for all equipment x 3.5BTU
= Total wattage for all lighting x 4.25BTU
= Number of occupants x 400BTU
= Length (m) x Width (m) x 337BTU
+ Total OccupantBTU
+ EquipmentBTU
+ LightingBTU
Note: the sample formulae are for the UK and Northern Europe in general and exclude any allowances for windows which can sometimes be found within very small server rooms.
At Server Room Environments are HVAC consultants and cooling experts manage an array of cooling projects from small air conditioners for server rooms to the large datacentre applications. One of the latest trends is to make use of adiabatic free cooling and especially in Northern Europe prior to this summers heatwave.
The current heatwave will subside eventually but the World in general is not getting any cooler. Weather patterns are changing and challenging traditional approaches to air conditioner and cooling system calculations. What we have provided here is a general guide and information to give you some idea of what to expect when sizing an air conditioner or cooling system. Please contact us for a specific site survey or discussion about your project with one of our HVAC engineers and project managers.
Are you interested in learning more about precision air conditioner solution provider? Contact us today to secure an expert consultation!